Map Using Prelookup
Use previously calculated index and fraction values to accelerate approximation of two-dimensional function
Libraries:
AUTOSAR Blockset /
Classic Platform /
Library Routines /
Interpolation
Description
The Map Using Prelookup block is intended for use with the
Prelookup block. This block enables a prelookup result to drive multiple
interpolation results. The Prelookup block calculates the index and interval
fraction that specify how its input value u
relates to the breakpoint data
set and feeds the resulting index and fraction values into a Map Using
Prelookup block to interpolate a two-dimensional table. The Prelookup
and Map Using Prelookup blocks have distributed algorithms that when used
together perform the same algorithm operation as the Map block, but offer
greater flexibility and more efficient simulation and code generation.
If you select the AUTOSAR 4.x code replacement library (CRL) for your AUTOSAR model, code generated from this block is replaced with the AUTOSAR library routine that you configure in the block parameters dialog box.
Ports
Input
Inputs to the kf1 port contain index k
and
fraction f
, specified as either
Ifx_DPResultU16_Type
or
Ifl_DPResultF32_Type
.
When Targeted Routine Library
is set to IFX
(fixed-point)
then the port is set to data type
Ifx_DPResultU16_Type
.
When Targeted Routine Library
is set to IFL
(floating-point)
then the port is set to data type
Ifl_DPResultF32_Type
.
Inputs to the kf2 port contain index k
and
fraction f
, specified as either
Ifx_DPResultU16_Type
or
Ifl_DPResultF32_Type
.
When Targeted Routine Library
is set to IFX
(fixed-point)
then the port is set to data type
Ifx_DPResultU16_Type
.
When Targeted Routine Library
is set to IFL
(floating-point)
then the port is set to data type
Ifl_DPResultF32_Type
.
Output
Approximation of the two-dimensional function computed by interpolating table data
that uses values from the input index, k
, and the fraction,
f
.
When Targeted Routine Library
is set to IFL
(floating-point)
then the only valid data type is
single
.
When Targeted Routine Library
is set to IFX
(fixed-point)
then you can the values of the Port 1
can be one of these data types: int8
, uint8
,
int16
, uint16
, int32
,
uint32
, and fixed-point data types.
Data Types: single
| int8
| uint8
| int16
| uint16
| int32
| uint32
| fixed point
Parameters
If you select the AUTOSAR 4.x code replacement library (CRL) for your model, code generated from this block is replaced from the selected AUTOSAR routine library. This parameter enables you to choose either fixed-point (IFX) or floating-point (IFL) code replacement and validation checks.
This parameter reflects the name of the AUTOSAR code replacement library (CRL) routine used to replace the code generated by this block. The naming convention includes the targeted routine library, interpolation method, and block type. This parameter is reference-only and must not be edited.
When the Targeted Routine Library
is set to IFX
(fixed-point)
the value defaults to Ifx_IpoMap
.
When the Targeted Routine Library
is set to IFL
(floating-point)
the value defaults to Ifl_IpoMap
.
Table Specification
Specify whether to enter table data directly or use a lookup table object. If you set this parameter to:
Explicit values
, the Table Data parameter and the Data Types tab are visible in the dialog box.Lookup table object
, the Name parameter is visible in the dialog box.
Programmatic Use
Block Parameter:
TableSpecification |
Type: character vector | string |
Values:
"Explicit values" | "Lookup table object" |
Default:
"Explicit values" |
Specify the name of a Simulink.LookupTable
object. A lookup
table object references Simulink.Breakpoint
objects. If a
Simulink.LookupTable
object does not exist, click the action button
and select Create. The
corresponding parameters of the new lookup table object are populated with the block
information.
Dependencies
To enable this parameter, set Data Specification to
Lookup table object
.
Programmatic Use
Block Parameter:
LookupTableObject |
Type: character vector |
Value:
Simulink.LookupTable object |
Default:
'[]' |
Enter the table of output values.
During simulation, the matrix size must be two-dimensional. However, during block
diagram editing, you can enter an empty matrix (specified as []
) or
an undefined workspace variable. This technique lets you postpone specifying a
correctly dimensioned matrix for the table data and continue editing the block
diagram.
Dependencies
To enable this parameter, set Data specification to
Table and breakpoints
.
Programmatic Use
Block Parameter:
Table |
Type: character vector |
Values: matrix of table values |
Default:
'[4 5 6;16 19 20;10 18 23]' |
Click this button to open the Lookup Table Editor.
Clicking this button for a lookup table object lets you edit the object and save the new values for the object.
Algorithm
Specify the method that the block uses to interpolate table data. You can select
Linear point-slope
, Flat
, or
Nearest
. For more information regarding these methods, see Interpolation Methods.
Programmatic Use
Block Parameter:
InterpMode |
Type: character vector | string |
Values:
"Flat" | "Linear point-slope" | "Nearest" |
Default:
"Linear point-slope" |
Specify the rounding mode for fixed-point or floating-point lookup table calculations that occur during simulation or execution of code generated from the model.
This option does not affect rounding of block parameter values. Simulink™ rounds such values to the nearest representable integer value.
Dependencies
This parameter is visible only when set to Round
.
Integer rounding is not supported for AUTOSAR 4.x and host libraries for SIL testing
and is hidden by default. To enable SIL workflows while using the AUTOSAR 4.x code
replacement library, change this setting to Zero
.
Programmatic Use
Block Parameter:
RndMode |
Type: character vector | string |
Values:
"Round" | "Zero" |
Default:
"Zero" |
Data Types
Specify the table data type. The block will validate that the selected types are compatible with the specification of the targeted routine.
When Targeted Routine Library
is set to IFL
(floating-point)
then the only valid data type is
single
.
When the Targeted Routine Library
is set to IFX
(fixed-point)
you can set the table data type to:
Rules that inherit a data type:
Inherit: Same as output
,Inherit: Inherit from 'Table data'
.One of these built-in data types:
int8
,uint8
,int16
,uint16
,int32
,uint32
.The name of a data type object, for example, a
Simulink.NumericType
object.An expression that evaluates to a data type. For example, the software provides these fixed-point data type expressions:
fixdt(1,16)
,fixdt(1,16,0)
, orfixdt(1,16,2^0,0)
.
Click the Show data type
assistant button to display the Data Type
Assistant, which helps you set the data type attributes. For more
information, see Specify Data Types Using Data Type Assistant.
Tip
Specify a table data type different from the output data type for these cases:
Lower memory requirement for storing table data that uses a smaller type than the output signal
Sharing of prescaled table data between two Curve blocks with different output data types
Sharing of custom storage table data in the generated code for blocks with different output data types
Dependencies
To enable this tab, on the Table Specification tab, set
Data Specification to Explicit
values
.
Programmatic Use
Block Parameter:
TableDataTypeStr |
Type: character vector | string |
Values:
"Inherit: Inherit from 'Table data'" | "Inherit: Same as output" |
"single" | "int8" | "uint8" | "int16" | "uint16" | "int32" | "uint32" |
"fixdt(1,16)" | "fixdt(1,16,0)" | "fixdt(1,16,2^0,0)" | "<data type
expression>" |
Default:
"Inherit: Same as output" |
Extended Capabilities
C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.
Version History
Introduced in R2019aInteger rounding mode is set to "Zero"
and hidden by default because only "Zero"
is
supported for AUTOSAR 4.x and host libraries for SIL testing.
Starting in 25a, the AUTOSAR code replacement library supports AUTOSAR schema versions
after AUTOSAR 4.0. To use the latest AUTOSAR routines, in the model Configuration Parameters
dialog box in the Code Generation > Interface pane, specify Code replacement libraries as
AUTOSAR 4.x
.
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)