ssSetParameterTuningCompliance
Specify sample time behavior and tunability for S-function blocks with port-based sample times
Syntax
void ssSetParameterTuningCompliance(SimStruct *S,logical Flag)
Arguments
S
SimStruct that represents an S-function block.
Flag
Logical value indicating whether to allow a sample time of
Inf
for ports in the S-function.
Description
Use this macro to specify sample time behavior for your S-function with port-based
sample times. If you set flag
to False
, the
Simulink® engine does not allow a sample time of Inf
for this
S-function. If you set flag
to True
, the
S-function block is tunable and its ports can have a sample time of
Inf
. To set the sample time for ports in the S-Function, use
ssSetOutputPortSampleTime
and
ssSetInputPortSampleTime
. These
ports execute every time you tune any parameter in your model during
simulation.