System Identification toolbox, can't import frequency domain data above frequency of pi rad/s
1 view (last 30 days)
Show older comments
Olav W. Alstad
on 24 Feb 2015
Commented: Olav W. Alstad
on 24 Feb 2015
I'm using the System Identification toolbox to approximate a transfer function from frequency domain data. The data is numerical values of a frequency function (complex) in the range of 0.63 rad/s too 94.25 rad/s (0.1 Hz - 15 Hz). The problem is that frequency function above pi rad/s (3.14 rad/s) will not be imported. If the frequency is scaled down, such that the max frequency is lower than pi rad/s, the whole frequency function is sucsessfully imported.
It might be a simple answer to this question, but I've no idea. Thanks for helping me :)
0 Comments
Accepted Answer
Arkadiy Turevskiy
on 24 Feb 2015
You are forgetting to set the sample time somewhere in your code or in the app. The tool will show the data up to the Nyquist frequency. So if you leave sample time at default Ts=1 sec, that would be 0.5*(1/Ts)*2pi=pi rad/sec.
D you know the sampling time your data was collected at? Say if it was 100 samples/sec, Nyquist frequency would be 0.5*(100)*2*pi=314 rad/s, allowing you to see all your data.
More Answers (0)