Resampling data without altering the frequency of the data

16 views (last 30 days)
Dear matlab forum,
For my research I have to normalise EMG data for different subjects, so they all have the same amount of samples.
Now, via your forum someone recommend me to use 'interp1' and 'pchip'.
I tested this on a sinusoid with 1000 samples, that runs exactly 1 second.
When I plot this sinusoid, with % reduction in samples, I see that the frequency is affected (see picture).
I'm afraid that this also happens in my EMG data when I resample using this method. Since the end result of the research
is to assess the complexity of EMG signals, I want to preserve as much of the frequency content as possible, but I have to 'resample' to normalise
the amount of samples between subjects, since it is shown that a difference in samples causes different complexity outcomes.
What method could you recommend me to use to resample my data?
Hope to hear,
Jeroen

Accepted Answer

Star Strider
Star Strider on 19 Aug 2020
The problem with the procedure you describe is that the requirements appear to be incompatible. Ideally, all the records will have the same sampling frequency.
I would use the Signal Ptocessing Toolbox resample function to resample them to the same sanpling frequency, then truncate all of them to the length of ths shortest record. Exactly how you do that is your choice.
  10 Comments
Jeroen Vermeulen
Jeroen Vermeulen on 20 Aug 2020
I started to worry since you can see a slight difference in signals (see attachment in previous comment), when you compare the one sided plots of %1 and %2. I didn't see where this difference was coming from. Anyway, I'm glad I'm on the right track and thanks for taking the time to reply once more. Greatly appreciated Star :)

Sign in to comment.

More Answers (0)

Tags

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!