Answered
I am getting error in results while using my simulink PMSM model
The model runs in variable-step, but the maximum step size is not small enough to capture the AC quantities. By setting the Max ...

8 months ago | 0

Answered
How to remove generators from matpower
MATPOWER is not developed by MathWorks. It is best to consult the documentation of this third party tool or contact its develope...

8 months ago | 0

Answered
I am getting wrong value for Power calculation
It appears that the wrong block is used to compute the power. Power (Phasor) will compute active and reactive powers using volta...

8 months ago | 0

Answered
PWM signal goes to zero when using PID controller after MPPT (P&O) in PV system
Most likely the output of the PID controller is <=0 which will result in PWM signal to be 0. Double check the corectnes of the c...

9 months ago | 0

Answered
how to solve this problem
Without a model is not possible to point to the root cause but the problem is, as the error points out, the control port of a mu...

9 months ago | 0

Answered
Cannot connect Battery to Servomotor
Try using blocks from the same technology. In Simscape Electrical there are two technologoies, Simscape and Specialized Power Sy...

9 months ago | 0

Answered
implementing a two-loop PI controller for both current and voltage - buck converter
There are many relevant examples in Simscape Electrical to start with. Check out this bidirectional DC-DC converter current cont...

9 months ago | 0

Answered
implement a photovoltaic generator of energy in Simulink/matlab
Simscape Electrical has an example that shows the design of a stand-alone solar photovoltaic (PV) DC power system with battery b...

9 months ago | 0

Answered
Connect MATPOWER with Simulink model
MATPOWER is not developed by MathWorks. Probably best to check the documentation for this 3rd party tool.

9 months ago | 0

Answered
how to use MATPOWER for opf in case6
MATPOWER is not developed by MathWorks. Probably best to check the documentation for this 3rd party tool.

9 months ago | 0

Answered
How to open the electrical switch again after it closed
You can use a Pulse Generator block to control the switch: https://mathworks.com/help/simulink/slref/pulsegenerator.html You ca...

9 months ago | 0

Answered
Battery charging through PMSG while rotor of PMSG rotate with pedal of bike
A good place to start is this example: https://mathworks.com/help/sps/ug/pm-generator-for-battery-charging.html This example sh...

9 months ago | 0

Answered
PMLSM force and back-EMF constant
The back EMF constant is the peak voltage induced by the permanent magnet in the per-unit rotational speed of each of the phases...

9 months ago | 0

Answered
matpower8.0 comes with most test failed
MATHPOWER is not developed by MathWorks. Would be more suitable to get in touch directly with the developers of this 3rd party t...

9 months ago | 0

Answered
Simscape Bidirectional DC-DC Converter: Gate Control Input Type and Parameter Calculation Issues
With the Bidirectional DC-DC Converter, input G is always a vector. In the nonisolated variant we have two switches and therefor...

9 months ago | 0

Answered
How to compute dq current in a delta-wound motor?
From the control design point of view there is no difference between wye or delta windings. However, some inputs required by the...

9 months ago | 0

| accepted

Answered
vector control synchronous machine Simulink
Simscape Electrical has an example showing how to control the torque in an externally excited synchronous motor (SM) drive by us...

10 months ago | 1

Answered
Question about the OCV of Fuel cell block example from ee lib
This behaviour is because we are changing the pressure of fuel from 2.5 to 5 bar. By increasing the pressure this will increase ...

10 months ago | 0

Answered
Can the Motor & Drive (System Level) Simscape Electrical block be used to model an BLDC + Inverter power generator?
The Motor & Drive (System Level) block can operate in four quadrants and you can simulate the behaviour of a BLDC drive. Specify...

10 months ago | 0

Answered
Best practice for setting Simulink block parameters at initialization?
If you want easily to switch the system, I will probably use variants. Check out this example as a starting point: https://math...

10 months ago | 0

| accepted

Answered
I am having connection error of transformer with the asynchronous machine/ wind turbine (DFIG)
This is specific to specialized power systems. Inductors are modelled as current sources and cannot be in series without an alte...

10 months ago | 0

Answered
i want to ask question about the default example of battery state of health simulation in simscape.
This example has been configured such that it shows how the algorithm works and is not intended as a realistic battery parameter...

10 months ago | 1

| accepted

Answered
Three-Phase 3-Level Inverter with GaN
In simscape electrical you can use the N-Channel MOSFET block to model GaN devices: https://mathworks.com/help/sps/ref/nchannelm...

10 months ago | 1

| accepted

Answered
three-phase inverters NPC, ANPC, TNPC
The Modular Multilevel Converter (Three-Phase) can not be configured to the mentioned topologies. You can build these topologies...

10 months ago | 1

| accepted

Answered
Multilevel inverter with PSMS control
Check for example this: https://mathworks.com/help/sps/ug/torque-control-in-three-level-converter-fed-asynchronous-machine-driv...

10 months ago | 0

Answered
What is the reference positive direction of pmsm model in simscape with delta-wound configuration
The reference is the same. In delta-wound configuration we have line voltages which are defined as Vab, Vbc, Vca. From the contr...

11 months ago | 0

| accepted

Answered
Each physical network must be coHow to clear this error on simulink. (There is no Solver Configuration block connected to Physical Network with the following blocks)
Each physical network represented by a connected Simscape™ block diagram requires solver settings information for simulation. Th...

11 months ago | 0

Answered
Hi everyone. I am a student. I need this model block or similar blocks (wind power plant.)
Simscape Electrical has many examples of renewable energy sources, including wind generation. A good starting point is: https:...

11 months ago | 0

| accepted

Answered
matlab中自带的PMSM模型含有扰动吗?
Disturbances are internal and external factors. In PMSM load variation is a disturbance and this can be easily provided through ...

12 months ago | 1

Answered
sine pwm control for statcom
You will have three sinusoidal reference signals that you need to compare with a high frequency triangular signal carrier. The i...