Answered
What the relationship among flux linkage / back EMF constant and torque constant ?
Both definitions of torque constant Kt are correct. The second definition takes into account also the 3/2 factor from the torque...

7 years ago | 1

| accepted

Answered
State space modelling of a Mechanical System with Synchronous Motor
For such a system it is not common to combine all equations into a single model. It might end up with a very complex nonlinear m...

7 years ago | 0

| accepted

Discussion


Interlock/dead times in power converters
When it comes to interlock time (or dead-time) between gate signals of two complementary semiconductor devices, we tend to assum...

7 years ago | 1

Answered
Error using Simscape Eletrical - Boost Converter component
I was able to reproduce the problem. It seems that for the Boost Converter block there was a build issue. If you change the defa...

7 years ago | 2

| accepted