Detect usage of asynchronous reset signals
Specify whether to check for asynchronous reset signals in the generated code
Since R2020b
Model Configuration Pane: Global Settings / Coding standards
Description
Specify whether to check for asynchronous reset signals in the generated code. This check corresponds to CGSL-2.C.C.6 of the Industry standard guidelines.
Dependencies
To clear the Detect usage of asynchronous reset signals check box, set the HDL coding standard parameter to Industry
.
Settings
off
(default) | on
Default: Off
on
Check for asynchronous reset signals in the generated code.
off
Do not check for asynchronous reset signals in the generated code.
Tips
To set this property:
Create an HDL coding standard customization object.
cso = hdlcoder.CodingStandard('Industry');
Set the
AsynchronousResetCheck
property of the HDL coding standard customization object.For example, to minimize use of variables, enter:
cso.AsynchronousResetCheck.enable = true;
Set the
HDLCodingStandardCustomizations
property to the HDL coding standard customization object, specify the coding standard, and generate code.For example, if your DUT is
sfir_fixed/symmetric_fir
, enter:makehdl('sfir_fixed/symmetric_fir', 'HDLCodingStandard','Industry', ... 'HDLCodingStandardCustomizations',cso);
Recommended Settings
No recommended settings.
Programmatic Use
Parameter:
AsynchronousResetCheck property
of hdlcoder.CodingStandard
object |
Type: character vector |
Values: 'on' | 'off' |
Default: 'off' |
Version History
Introduced in R2020b