Model Referencing
hisl_0037: Configuration Parameters > Model Referencing
ID: Title | hisl_0037: Configuration Parameters > Model Referencing | |
---|---|---|
Description | Set these Configuration Parameters as follows: | |
A | Rebuild to | |
B | Never rebuild diagnostic to | |
C | Clear Minimize algebraic loop occurrences. | |
Rationale | A | To prevent unnecessary regeneration of the code, resulting in changing only the date of the file and slowing down the build process when using model references. |
B | For safety-related applications, an error should alert model developers that the parent and referenced models are inconsistent. | |
C | To be compatible with the recommended setting of Single output / update function for embedded systems code. | |
Model Advisor Checks | Check safety-related model referencing settings (Simulink Check) | |
References |
| |
See Also | Model Configuration Parameters: Model Referencing | |
Last Changed | R2024a - Removed support of configuration parameter Pass fixed-size scalar root inputs by value for code generation. |