jc_0171: Clarification of connections between structural subsystems
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
NA-MAAB — No recommendations
JMAAB — a, b
MATLAB Versions
All
Rule
Sub ID a
A minimum of one signal line shall connect two structural subsystems.
When a two-way signal connection exists between two structural subsystems (A and B), each direction shall be connected to at least one signal line.
Not Applicable
Sub ID b
Signals that are not used within a structural subsystem shall be input to a structural subsystem. These signals shall not be output to other structural subsystems or basic blocks.
Not Applicable
Signals that are not used in the subsystem are connected to avoid crossing of signal lines.
Rationale
Sub ID a:
Clarifies structural subsystem connections and execution order.
Sub ID b:
Eliminating unnecessary connections clarifies the relationship between connections.
Deviation from the rule can cause to confusion due to unused input/output signals.
Verification
Model Advisor check: Check connections between structural subsystems (Simulink Check)
Last Changed
R2020a
See Also
Version History
Introduced in R2020a