Main Content
jc_0792: Unused Data
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow®
Sub ID Recommendations
NA-MAAB — a, b
JMAAB — a, b
MATLAB Versions
All
Rule
Sub ID a
The data dictionary (sldd
) shall define only the data that is
used in the Simulink or Stateflow
Coder™ model.
Custom Parameter
Types of data dictionary
Sub ID b
The model workspace shall define only the data that is used in the Simulink or Stateflow model.
Custom Parameter
Not Applicable
Rationale
Sub IDs a, b:
Unused data can affect maintainability and operability.
Verification
Model Advisor check: Check unused data in Simulink Model (Simulink Check)
Last Changed
R2020a
See Also
Version History
Introduced in R2020a