How can I set up the lookup table for a 2-way directional valve?
4 views (last 30 days)
Show older comments
I need help with why I am getting this error "Dimensions of arrays being concatenated are not consistent. "
I am trying to model a 2-Way Driectional Valve using lookup tables.
4 Comments
Voss
on 14 Apr 2022
No idea, sorry. Apparently that's some stuff from Simscape, which I've never used.
Answers (1)
Yifeng Tang
on 24 Jun 2022
Regarding the error message in you comment:
- ['Trial/2-Way Directional Valve (IL)']: Size of Volumetric flow rate table, q(s,dp) must be equal to length of Spool travel vector, s by length of Pressure drop vector, dp. In fluids.isothermal_liquid.valves_orifices.directional_control_valves.directional_valve_2_way
It's complaining about size(q) is not the save as [length(s),length(dp)]. q is what you have put in the volumetric flow rate table, and s is the spool travel vector, and dp is the pressure drop vector. The dimensions have to be right, or Simscape doesn't know how to do the look up.
0 Comments