Hello,
I try to deploy a simple model to my Texas Insturments Experimenter's Kit powered by an F28035 MCU, but during Monitor & Tune in R2022a, I fail to connect to it.
What happens is that the code gets build and deployed to the MCU, but then the connection fails with:
| External Mode Open Protocol Connect command failed
| Caused by: Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command
| Component:Simulink | Category:Block diagram error
The model that I use is:
The hardware configuration is:
The External Mode is setup as:
Finally, the SCI_A that should be used by XCP is configured as:
Isn't XCP connection achieved via the XDS100v2 probe, or what is wrong?
Thanks,
Robin

Accepted Answer

Nathan Hardenberg
Nathan Hardenberg on 27 Jun 2023
I had this Problem with the Piccolo F280049C Launchpad and had to change the COM-Port (which is COM4 in your case):
Model Settings > Hardware Implementation > Target hardware resources > External mode > Serial port (...)
In Device-Manager check for the COM-Port with "User UART". For me by default the other COM-Port (Auxiliary Data Port) was selected. After the change "Monitor & Tune" worked as expected. Maybe this can also help you, even if it is not the same board/processor
  7 Comments
ali
ali on 26 Aug 2023
thank you man, it work completely and I connect to borad in external mode.
Robin Molnar
Robin Molnar on 26 Aug 2023
You are most welcome, @ali!

Sign in to comment.

More Answers (1)

VINODH KUMAR
VINODH KUMAR on 7 Jul 2025
I faced the same issue. Its about choosing the correct com port and SCI settings.
i am using launchxl f28069.
The default SCI settings for me is Tx - GPIO29, Rx - GPIO28.
default SCI settings
and from the datasheet of launchxlf28069