HDL Coder "Requested CP number exceeds total number of register-to-register CPs"
7 views (last 30 days)
Show older comments
Hello,
I am running the HDL Workflow Advisor on a simple model which is attached to this request. The settings for the HDL Workflow Advisor are the same like proposed here (Synthesis tool: Xilinx ISE, Family: Kintex7).


Inspite of the simple model I am getting the error "Failed Requested CP number exceeds total number of register-to-register CPs generated during synthesis. Please check whether there is any register to register path in the model." during "4.3 Annotate Model with Synthesis Result" in "4. FPGA Synthesis and Analysis".

Could you please help me to find the reason for that failure?
Thanks in advance and best regards,
Tom
0 Comments
Accepted Answer
Tim McBrayer
on 16 Apr 2015
CP stands for Critical Path. You have requested critical path analysis on your model, which will analyze the post-synthesis results and backannotate the timing information between registers onto the Simulink diagram. But, since you don't have any registers at all in your design, the critical path analysis can find no register-to-register paths. This is what the message is attempting to inform you of.
3 Comments
Walter Roberson
on 13 Aug 2015
Either add registers to your design or turn off critical path analysis.