Hi, There is a subsystem in my model.The model's sample time is 0.0001,and i want to set some block's sample time in the subsystem 0.0005.But when i click the build button ,i got the error as follows:
Error building Real-Time Workshop target for block diagram '2812_StepTime'. MATLAB error message: '2812_StepTime/Function-Call Subsystem/Counter Limited/Output' has an invalid sample time. Only constant (inf) or inherited (-1) sample times are allowed in the asynchronous subsystem '2812_StepTime/Function-Call Subsystem/Counter Limited'
How could solve this problem?
My matlab version: 2009a
Best regards.
0 Comments
Accepted Answer
Titus Edelhofer
on 18 Nov 2011
Hi,
this can't work: you call you subsystem with a function call asynchronously, so blocks inside the subsystem have no "direct" control about when the subsystem is called. How could a block inside impose a sample time? It would need to carry this information to the containing subsystem... Perhaps you could explain in more detail why a block inside the fcn call subsystem should have a fixed sample time...
Titus
2 Comments
Titus Edelhofer
on 18 Nov 2011
One way to overcome many problems: move the offending block outside the subsystem and feed the output of the block as an input to the subsystem (probably using a rate transition block in between). Further advice is I guess only possible with more information aout why you want to have a fixed sample time block in your subsystem.
More Answers (1)
Fangjun Jiang
on 18 Nov 2011
It makes sense, right? Your "2812_StepTime/Function-Call Subsystem/" is a function-call system, which could be called irregularly, depending on where the function call trigger comes from. Thus, it can not guarantee the inside block "Counter Limited/Output" be called in a fixed rate.
It sounds like you are using a function call generator block with a fixed sample rate. Why not try to specify your subsystem as an atomic subsystem with a fixed sample rate of 0.0001. I believe that will get rid of the error.