I don' know why simulink parameter estimation failed. Please help me

78 views (last 30 days)
I want to know battery’s internal parameter (internal resistance, diffusion reisister, tau) when i modelling a battery to ECM using a simscape battey.
For parameter estimation, I use hppc profile for input
i make a new experience in parameter estimation app and choose parameter i want to know. Then Run estimating
Simulated Output cannot follow the experienced output.. Cost is also too high.
For Result parameter is not converged..
what’s wrong.. is it important parameter’s initial value, min, max?
Is Input signal too complicated to estimate parameters?
Please give me some tips. Expert of simulink members..
[Below, Text in report translated in English ]
' Optimization started on 2024-Nov-11, 10:50:02.
Estimation converged on 2024-Nov-11, 11:24:53.
One error occurred in the solver during estimation. For more details on the error, check 'EvalErrors_2' in the results workspace.
'ingyu' has been updated with the estimated parameter values.
The estimated parameter values are recorded in 'EstimatedParams'.
The estimated experiment values are recorded in 'Exp'.
Solver output for estimation:
A local minimum may exist.
lsqnonlin stopped because the final change in the sum of squares relative to the initial value was smaller than the function tolerance.
<Details of the stopping criterion>
Optimization stopped because the relative change in the sum of squares (r) was smaller than options.FunctionTolerance = 1.000000e-03.'
  3 Comments
인규
인규 on 11 Nov 2024 at 4:15
.
EvalErrors_2 is same as EvalErrors.
when i used fast reload option, Error occured.
not using fast option error didn't occured and parameter estimation was completed. But it was not correct.
Walter Roberson
Walter Roberson on 11 Nov 2024 at 17:59
Sorry, I am unable to change how Simulink FastRestart works so that it will permit changing those parameters. You could file an enhancement request to permit parameters to be changed for FastRestart.

Sign in to comment.

Answers (1)

Yifeng Tang
Yifeng Tang on 20 Nov 2024 at 14:25
Looks like the error message is trying to tell you that the Parameter Estimater cannot change the parameters it tries to estimate. This is because the "compile-time" parameters in Simscape (to be explained later) can't be modified from simulation to simulation when the Fast Restart is turned on. The solution is simple:
(1) NOT recommended: turn off fast restart. This will allow the parameters to be modified, but also add compile time to the start of each simulation.
(2) Do this instead: for the parameters you try to estimate, at every place it's used, make them "run-time". This way, Simscape will keep a placeholder for them and allow the values to be modified from run to run in Fast Restart mode.
See these two documentation pages for more details:
The 2nd page talks about runing run-time parameters with fast restart. It's a common practice when doing parameter estimation.
  3 Comments
Yifeng Tang
Yifeng Tang on 21 Nov 2024 at 14:37
It would indeed be nicer if the simulation runs fast during a parameter estimation exercise because the model has to run many times. Fast Restart feature only reduces the "compile" time but has no impact on the simulation time.
There can be a LOT of reasons that may affect your simulation speed. I can't give more specific help without seeing the actual model. Is that something you can share?
인규
인규 about 1 hour ago
Sure, it's just simple model for battery charge/discharge.
Because the Real battery experiment time is long, model's simulation time is also long.
Real battery experiment's total measurement time i 72:05:50s. And measurement time interval is once a 0.1s

Sign in to comment.