Hi,
I have been reading through the simulink documentation on how the simulink engine executes a model. However, I am still unclear regarding what happens in the case of overload (i.e., CPU is too busy for completing execution by the next simulation round). Could someone explain simulink's behavior in this case or point me to the appropriate documentation?
Thank you! -- Octav
0 Comments
Answers (1)
Kaustubha Govind
on 22 May 2012
Simulink/MATLAB would simply wait for a CPU cycle, just like any other software on a non-real-time OS. In other words, the model execution is single-threaded, so the next time-step is not reached until the current step is complete.