what is the units of angle random walk in (Inertial Sensor Noise Analysis)

26 views (last 30 days)
hello
i wants to know the units of angle random walk, Rate Random Walk, Bias Instability mentioned in
thanks

Answers (1)

Diarmaid Cualain
Diarmaid Cualain on 4 Mar 2021
Edited: Diarmaid Cualain on 4 Mar 2021
Yea, it isnt clear in the documentation.
  • ARW is (rad/s)/√Hz.
  • RRW is (rad/s)(√Hz).
  • Bias instability is rad/s.
You can tell, because at the end of the guide they use the function https://uk.mathworks.com/help/fusion/ref/gyroparams.html where the units are listed.
  • ARW is also called N, white noise, noise density or power spectral density of sensor noise.
  • RRW is also called K, red noise, Brownian noise. It is the integrated white noise.
  • Bias instability is also called B, pink noise, flicker, or instability of the bias offset
  1 Comment
Mazen Maged
Mazen Maged on 16 Apr 2021
Hi Diarmaid,
Could you explain what are the units of Allan Variance and Allan Deviation used in the example? I think they should depend on the units of omega (rad/s)?

Sign in to comment.

Categories

Find more on Specialized Power Systems in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!