Series C
Model series capacitor
Libraries:
RF Blockset /
Equivalent Baseband /
Series /
Shunt RLC
Description
The Series C block models the series capacitor described in the block dialog box, in terms of its frequency-dependent S-parameters.
The series C object is a two-port network, as shown in the following circuit diagram.
Parameters
Main
Capacitance (F) — Capacitance of the series element
1e-12
(default) | scalar
Scalar value for the capacitance. The value must be non-negative.
Visualization
Source of frequency data — Frequency data source
User-specified
(default)
Frequency data source, specified as
User-specified
.
Frequency data (Hz) — Frequency data range
[1:1.0e5:4e6]
(default) | vector
Frequency data range, specified as a vector in hertz.
Reference impedance (ohms) — Reference impedance
50
(default) | nonnegative scalar
Reference impedance, specified as a nonnegative scalar in ohms.
Plot type — Type of data plot
X-Y plane
(default) | Composite data
| Polar plane
| Z Smith chart
| Y Smith chart
| ZY Smith chart
Type of data plot to visualize using the given data, specified as one of the following:
X-Y plane
— Generate a Cartesian plot of the data versus frequency. To create linear, semilog, or log-log plots, set the Y-axis scale and X-axis scale accordingly.Composite data
— Plot the composite data. For more information, see Create Plots Using Equivalent Baseband Library Blocks.Polar plane
— Generate a polar plot of the data. The block plots only the range of data corresponding to the specified frequencies.Z smith chart
,Y smith chart
, andZY smith chart
— Generate a Smith® chart. The block plots only the range of data corresponding to the specified frequencies.
Y parameter1 — Type of parameters to plot
S11
(default) | S12
| S21
| S22
| GroupDelay
| OIP3
| NF
| ...
Type of parameters to plot based on the Plot type you set, specified as one of the following.
Plot type | Y parameter1 |
---|---|
X-Y plane | S11 , S12 , S21 , S22 , GroupDelay , OIP3 , NF , NFactor , and NTemp . |
Composite data | No Y parameter1 to set. |
Polar plane | S11 , S12 , S21 , and S22 |
Z Smith chart | S11 and S22 . |
Y Smith chart | S11 and S22 . |
ZY smith chart | S11 and S22 . |
Y parameter2 — Type of parameters to plot
S11
(default) | S12
| S21
| S22
| GroupDelay
| OIP3
| NF
| ...
Type of parameters to plot based on the Plot type you set, specified as one of the following.
Plot type | Y parameter2 |
---|---|
X-Y plane | S11 , S12 , S21 , S22 , GroupDelay , OIP3 , NF , NFactor , and NTemp . |
Composite data | No Y parameter2 to set. |
Polar plane | S11 , S12 , S21 , and S22 |
Z Smith chart | S11 and S22 . |
Y Smith chart | S11 and S22 . |
ZY smith chart | S11 and S22 . |
Y format1 — Plot format
Magnitude (decibels)
(default) | Mag
| Magnitude (linear)
| Angle
| Real
| Imaginary
| ...
Plot format, specified as one of the following.
Y parameter1 | Y format1 |
---|---|
S11 , S12 , S21 , and S22 . | Magnitude (decibels) , Magnitude (linear) , Angle(degrees) , Angle(radians) , Real , and Imaginary . |
GroupDelay | ns , us , ms , s , and ps . |
OIP3 | dB , dBm , W , and mW . |
NF | Magnitude (decibels) |
NFactor | None |
NTemp | Kelvin |
Dependencies
To enable Y format1, set Plot type to X-Y plane
.
Y format2 — Plot format
Magnitude (decibels)
(default) | Mag
| Magnitude (linear)
| Angle
| Real
| Imaginary
| ...
Plot format, specified as one of the following.
Y parameter2 | Y format2 |
---|---|
S11 , S12 , S21 , and S22 . | Magnitude (decibels) , Magnitude (linear) , Angle(degrees) , Angle(radians) , Real , and Imaginary . |
GroupDelay | ns , us , ms , s , and ps . |
OIP3 | dB , dBm , W , and mW . |
NF | Magnitude (decibels) |
NFactor | None |
NTemp | Kelvin |
Dependencies
To enable Y format2, set Plot type to X-Y plane
.
X parameter — Frequency plot
Freq
(default)
Frequency plot, specified as Freq
.
X format — Frequency plot format
Auto
(default) | Hz
| kHz
| MHz
| GHz
| THz
Frequency plot format, specified as one of the following.
Auto | Hz | kHz | MHz |
GHz | THz |
Y scale — Y-axis scale
Linear
(default) | Log
Y-axis scale, specified as Linear
or Log
.
Dependencies
To enable this parameter, set Plot type to X-Y
plane
.
X scale — X-axis scale
Linear
(default) | Log
X-axis scale, specified as Linear
or Log
.
Dependencies
To enable this parameter, set Plot type to X-Y
plane
.
Plot — Plot specified data
button
Plot the specified data using the plot button.
Version History
Introduced before R2006a
See Also
General Passive Network | LC Bandpass Pi | LC Bandpass Tee | LC Bandstop Pi | LC Bandstop Tee | LC Highpass Pi | LC Highpass Tee | LC Lowpass Pi | LC Lowpass Tee | Series L | Series R | Series RLC | Shunt C | Shunt L | Shunt R | Shunt RLC
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Select a Web Site
Choose a web site to get translated content where available and see local events and offers. Based on your location, we recommend that you select: .
You can also select a web site from the following list
How to Get Best Site Performance
Select the China site (in Chinese or English) for best site performance. Other MathWorks country sites are not optimized for visits from your location.
Americas
- América Latina (Español)
- Canada (English)
- United States (English)
Europe
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)
Asia Pacific
- Australia (English)
- India (English)
- New Zealand (English)
- 中国
- 日本Japanese (日本語)
- 한국Korean (한국어)