Problem in importing spice model to Simulink
13 views (last 30 days)
Show older comments
I have imported a spice model to simulink, but it doesn't work. After getting the R8003KND3TL1.lib, I've run
subcircuit2ssc('R8003KND3TL1.lib','+mylibrary');
ssc_build mylibrary;
and got mylibrary_lib.slx which contains the model. I build a simple circuit as:
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/842020/image.png)
where Vdc = 400V, Vg = 0/4V according with the device, and R = 1000 ohm.
However, there is some error:
```
运行仿真时出错,仿真终止(Error running simulation, simulation terminated)
Reason: all components and nodal across variables involved
Cannot solve for one or more variables, including dynamic variable derivatives:
Time derivative of 'r8003knd3.M1.cap_cgdo.Qcap' (Charge)
Time derivative of 'r8003knd3.M1.cap_cgso.Qcap' (Charge)
Time derivative of 'r8003knd3.M1.mos_cin.Qd' (Drain charge)
'r8003knd3.M1.cap_cgdo.i' (Current)
'r8003knd3.M1.cap_cgso.i' (Current)
'r8003knd3.M1.mos_cin.Id' (Drain current)
all components and nodal across variables involved
Cannot solve for one or more variables, including dynamic variable derivatives:
Time derivative of 'r8003knd3.M1.cap_cgso.Qcap' (Charge)
Time derivative of 'r8003knd3.M1.mos_cin.Qb' (Bulk charge)
Time derivative of 'r8003knd3.M1.mos_cin.Qg' (Gate charge)
'r8003knd3.M1.cap_cgso.i' (Current)
'r8003knd3.M1.mos_cin.Ib' (Bulk current)
'r8003knd3.M1.mos_cin.Ig' (Gate current)
Problems possible for transient initialization, as well as stepsize control for transient solve, due to equations (including nonlinear equations) of one or more components:
all components involved
'untitled/r8003knd3'
Equation locations are:
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
Problems possible for transient initialization, as well as stepsize control for transient solve, due to equations (including nonlinear equations) of one or more components:
all components involved
'untitled/r8003knd3'
Equation locations are:
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\cap.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\cap.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\cap.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\cap.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
'D:\MATLAB\R2021b\toolbox\physmod\elec\library\m\+ee\+additional\+spice_semiconductors\spice_mos3_charge.sscp' (no line number info)
```
How do I solve the problem?
0 Comments
Answers (1)
Sabin
on 22 Dec 2022
The conversion is fine, it seems that the simulation model is a bit challenging for the continuous solver. The simple model will simulate with the local solver. For some help you can check the SPICE Conversion of a MOSFET Subcircuit and Validation workflow in Simscape Electrical. I hope this helps.