Is it possible to have tags=signal name in Simulink?

5 views (last 30 days)
The Goto and From blocks in Simulink are not using the signal names, they have there own "tag" name, which is anoying. Is there a switch somewhere to make the signal name and tag name the same always?

Answers (1)

Fangjun Jiang
Fangjun Jiang on 10 Nov 2022
No.
I could think of two reasons not to do that.
  1. In many models, many signal lines have no label (i.e. the "signal names" are empty or blank).
  2. I saw this problem happened quite a few times. In the model, there is a signal line with label (signal name) called "MySignal". It is resolved to a Simulink.Signal object called "MySignal" in the base workspace. If the tag of a Goto block is also set as "MySignal", then after a simulation, the saved signal logging "MySignal" would over-write the Simulink.Signal object "MySignal". There will be an error message for the next simulation.
There are measures available to avoid both. But considering these, I don't think "auto tagging signal name" is a good idea.