Fmu with “canBeInstantiatedOnlyOncePerProcess” = false
14 views (last 30 days)
Show older comments
I would like to create an fmu from a simulink model where the “canBeInstantiatedOnlyOncePerProcess” fmu variable is set to false rather than true. Is there a way to set this?
Answers (1)
Yash
on 23 Sep 2024
Edited: Yash
on 23 Sep 2024
The canBeInstantiatedOnlyOncePerProcess flag in modelDescription.xml can be set to true or false for a Simulink model with fixed-step solver by either:
1) Using CLI: By setting the value of parameter SupportMultiInstance as on or off in the function exportToFMU (https://www.mathworks.com/help/slcompiler/ref/exporttofmu.html#mw_543093a5-7db7-4a99-82fa-2ab09dbc03c6) The flag is set to false when this parameter is specified as on.
2) From GUI: By selecting the check box "Support multiple instantiation per process" in the Advanced tab of Export Model to Standalone FMU
This functionality seems to have been supported since MATLAB R2024b by MathWorks and is compatible with FMI 2.0 and 3.0 standards.
0 Comments
See Also
Categories
Find more on RF Blockset Models for Transceivers in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!