xcp on serial Custom board c2000

I connected my custom c2000 320f28335 mcu board via sci_a with com port to simulink for xcp debugging, but there is time out error on connection.
Is there any specific hardware configuration?
matlab version 2022b.
the error is :
Could not connect to target application: XCP internal error: timeout expired, in response to XCP CONNECT command

1 Comment

Sci-a connected to pc via USB to TTL device, on com port and I configured this port number in hardware configuration in simiulink and also I checked pin number of sci-a

Sign in to comment.

 Accepted Answer

ali
ali on 26 Aug 2023
in my case the problem was due to Gnd connection of board and USB to TTL device, I had not connected Gnd,
after I connect it, external mode works correctly

More Answers (0)

Categories

Find more on Deployment, Integration, and Supported Hardware in Help Center and File Exchange

Products

Release

R2022b

Asked:

ali
on 20 Aug 2023

Answered:

ali
on 26 Aug 2023

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!