Simscape Battery Block Parameterization Manager: Datasheet Derived Values for Terminal Resistance R0 of Molicel Battery Cell
10 views (last 30 days)
Show older comments
Fynn-Brian Semmler
on 31 Jan 2024
Commented: Fynn-Brian Semmler
on 7 May 2024
Hello,
i am using the Block Parameterization Manager: Battery (Table-Based) to use pre-parameterize battery cells in my Simulink Simscape model. I am wondering where some data is coming from, specifically the values for R0 (Terminal Resistance) of the Molicel INR_21700_P45B.
In the manager, its says datasheet derived. Is it possible to view this datasheet somewhere? Is there a database for it?
Thank you very much for your help!
Best
1 Comment
Kautuk Raj
on 15 Feb 2024
The datasheets can be typically found on the manufacturer website, in this case here: https://www.molicel.com/wp-content/uploads/INR21700P45B_1.2_Product-Data-Sheet-of-INR-21700-P45B-80109.pdf
Accepted Answer
Javier Gazzarri
on 6 May 2024
Hello Fynn-Brian
Thank you for your question.
The internal resistance is calculated based on pairs of constant current discharge curves as R ~ deltaV / delta I.
Please let me know if you have any other question.
Best regards,
Javier
More Answers (0)
See Also
Categories
Find more on Simscape Battery in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!