A bus data type should be specified for the block 'xxxx/Out' since a bus is entering its input port. This message is related to a hidden Outport block

61 views (last 30 days)
I have a Simulink model that have hundreds of output signals in a bus and output into a port. The simulink model runs without error, however the test harness throws error that says "A bus data type should be specified for the block 'xxxx/Out' since a bus is entering its input port. This message is related to a hidden Outport block". I am new to Simulink any help would be appreciated.

Answers (1)

Sachin Lodhi
Sachin Lodhi on 12 Feb 2024
The issue is related to the data type settings for the output port of a block within your model. In Simulink, when a bus signal is routed through a model, each block that outputs a bus signal must have its data type explicitly defined to match the structure and type of the bus. This includes not only Bus Creator blocks but also any other blocks that output bus signals, such as subsystems or custom blocks.
By specifying the bus object as the data type for the output ports that are issuing bus signals, you can resolve the type mismatch errors that Simulink reports.
  1 Comment
Matthew
Matthew on 12 Nov 2024 at 14:02
I am having the same issue, but once I rename the bus, I am having the data type flag up saying that I am missing variables?

Sign in to comment.