Fixed-step size: why doesn't the Nyquist-Shannon sampling theorem work?

17 views (last 30 days)
Hello,
My problem concerns the choice of fixed-step size (Model Settings > Solver details).
I have a sinusoidal signal of amplitude 3 and frequency 5Hz.
According to Shanon's theorem, I should choose a fixed-step size of 5Hz*2 = 10Hz. So I assigned 0.1 to fixed-step size. I chose "auto" solver.
But as you can see, I get a flat curve:
I have a much more better curve if I choose, for example, 0.01 as fixed-step size:
Thank you in advance for your help. I've been struggling this problem for a few hours now.

Accepted Answer

David Goodmanson
David Goodmanson on 27 Mar 2024
Edited: David Goodmanson on 27 Mar 2024
Hello Zahara,
The Nyquist theorem gives you the bare minimum number of points to describe the oscillation. More points are better, as you are finding out. Taking your case of 5 Hz, Nyquist frequency 10 Hz, then
t = 0:.1:1;
cos(2*pi*5*t)
ans = 1 -1 1 -1 1 -1 1 -1 1 -1
showing that there is a steady oscillation, but at just two points per oscillation, you can't see the shape of the cosine waveform at all
And
sin(2*pi*5*t)
1.0e-14 * [0 0.0122 -0.0245 -0.1409 -0.0490 0.0612 0.2818 -0.2695 -0.0980 0.1102]
which is essentially 0 since the time points match up with the zeros of the sine function. In practical terms, the Nyquist criterion is no help at all here. This may or may not be why you are obtaining the flat line.
  1 Comment
Zahara
Zahara on 30 Mar 2024 at 17:08
Thank you for your quick answer. I had a doubt about the explanation, it's solved now!

Sign in to comment.