Can i use battery pulse discharge data to calibrate the table-based battery model?
2 views (last 30 days)
Show older comments
SUDEEP SINGH RAWAT
on 25 Nov 2024
Commented: Mike Sasena
on 18 Dec 2024
Hello,
I am in between developing a lithium ion battery pack for thermal analysis. For this, i have taken table-based battery model. I also have DC electronic load tester which can perform pulse discharge test of the lithium ion cell. As far as i know, the HPPC test data is required to calibrate the battery cell model which is based on pulse charge and discharge of the lithium ion cell, but i only have discharging option. Can i calibrate my battery pack model with the experimental data of pulse discharge? Also, if any other option is available, please let me know.
Thank you.
0 Comments
Accepted Answer
Mike Sasena
on 25 Nov 2024
Hi Sudeep. Check out this example on fitting equivalent circuit battery models to test data. The process works with whatever data you give it, but if you provide only discharge data, you will only characterize the discharge behavior. You would expect different resistance in charge and discharge operation.
2 Comments
Mike Sasena
on 18 Dec 2024
Hi Sudeep. If you don't have any way to access a Windows or Linux machine, you could try using tools like Simulink Design Optimization or the Optimization Toolbox to set up the parameter estimation.
More Answers (0)
See Also
Categories
Find more on Battery Pack Modeling in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!