goto error when using more than one Single Phase Dynamic Load Block

hi I want to modeling IEEE 37 bus with simulink i want to modeling three phase unblanced constant current so i used Single Phase Dynamic Load Block but when I using more than one block i recive multipile goto error

1 Comment

Could you share your Simulink model with me? I only want to use it evaluate my calculation. Thank you!

Sign in to comment.

 Accepted Answer

This problem no longer happens in the latest version (R2015a), but I tried on an older version and that was indeed the case.
Not sure how safe this is, but I could resolve the issue by right-clicking the block, selecting "Properties", going to the "Callbacks" tab, and deleting the text in the "CopyFcn" callback. Apparently that callback modifies the names of a Goto block in the Controlled Current Source inside the block, which causes a conflict when you have multiple of them dragged in.
- Sebastian

More Answers (0)

Categories

Find more on Modeling in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!