Derivative of state '1' in block 'X/Y/Integrator' at time 0.55 is not finite.
695 views (last 30 days)
Show older comments
An error occurred while running the simulation and the simulation was terminated Caused by: Derivative of state '1' in block 'X/Y/Integrator' at time 0.55 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances). How to fix this error?
4 Comments
Sam Chak
on 14 Apr 2023
Hi @MASSAMBA
Please post your Simulink model (a snapshot) on a New Question. It allows to use to visually inspect if there is any block that cause the problem.
By the way, most of the time, the true singularity problem cannot be solved by merely reducing the fixed step size or by tightening the error tolerances. Take note!
Sourabh
on 22 May 2023
Edited: Walter Roberson
on 22 May 2023
mdl = 'rl_exam'
obsInfo = rlNumericSpec([2 1]);
obsInfo.Name = 'observations';
obsInfo.Description = 'integrated error and error';
actInfo = rlNumericSpec([1 1]);
actInfo.Name = 'PID output';
env = rlSimulinkEnv(mdl,[mdl '/RL Agent'],obsInfo,actInfo)
agentOpts = rlDDPGAgentOptions(...
'SampleTime',0.01,...
'TargetSmoothFactor',1e-3,...
'DiscountFactor',0.99,...
'ExperienceBufferLength',100000,...
'MiniBatchSize',64,...
'NumStepsToLookAhead',2);
agent = rlDDPGAgent(obsInfo,actInfo,agentOpts)
This is the code i am using and i am getting
- Algebraic state in algebraic loop containing 'rl_exam2/calculate reward/Sum1' computed at time 0.30000000000000004 is Inf or NaN. There may be a singularity in the solution. If the model is correct, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances) or tweak the initial guess of algebraic loop variable values.
as error . i dont know how to attach the simulink file. i am stuck from last 5 days on this, any help would be great.
Answers (10)
Sorelys Sandoval
on 21 Aug 2016
Hi, I had the same problem and the next thing worked for me:
Go to model configuration parameters/Solver/Solver Options:
Type: Variable-step
Solver: ode15s (stiff/NDF)
and that's all. Hope it works for you :D
20 Comments
Nicolas CRETIN
on 26 Apr 2024
Edited: Nicolas CRETIN
on 21 May 2024
I don't have exactly the same error, but the following has helped in my case: I reduced the relative tolerance in the solver parameters:
hope it can help someone!
Sebastian Castro
on 4 Nov 2015
This usually has to do with really large or infinite signals feeding into an Integrator block. Numerical solvers (expectedly) have trouble integrating such large signals and therefore this leads to errors.
Typical causes can be divide by zero (1/0 = inf) or general unstable dynamics that quickly blow up over time. You should check that in your model. It can help to use Port Value Displays as you step through the model to figure out why this happens.
- Sebastian
0 Comments
Abhiram V. P. Premakumar
on 1 Apr 2021
Edited: Abhiram V. P. Premakumar
on 30 Jun 2023
I solved this issue by eliminating the infinite signal, using a switch block, and setting a clock as it's threshold (or a step block with t=1e-3). Denominator of a DIVIDE block being 0 at the beginning of a simulation, was the issue in my case. Using a clock or a step signal starting at t=1e-3s, along with a switch block, can make the divide block in the output of the switch block use a finite value temporarily, until the actual signal becomes finite.
10 Comments
Abhiram V. P. Premakumar
on 30 Jun 2023
Denominator of a DIVIDE block being 0 at the beginning of a simulation, was the issue in my case. A clock or a step signal starting at t=1e-3s, can make the divide block use a finite value temporarily until the actual signal becomes finite.
Guy Rouleau
on 25 Jul 2024
I describe the most common reasons for this error in this blog post:
The most common causes are:
- A modeling error making the equations diverging
- Too large step size
- Division by zero
4 Comments
文德
on 13 Dec 2024 at 9:45
Hello! I have built a motor simulation circuit, and I encounter an error when running it, as shown in the image. I have been unable to find a solution. Could you please help me identify the problem and suggest how to resolve it? Thank you!
Walter Roberson
on 13 Dec 2024 at 20:25
@文德
Compiling the model reports several input and output ports of various Mux are not connected.
It also reports,
Warning: Derivative block 'untitled/转矩绕组电压模块2/Derivative1' might produce unexpected or incorrect output values because the input
signal is not differentiable. Consider changing the model so the input signal has continuous sample time or implementing the
derivative using a Transfer Fcn block instead of the Derivative block.
and the same for Derivative2
Meanwhile, the input signal i4d is going to at least 1e+184 at time 0.0009
ahmet akgün
on 2 May 2021
Adaptive Sliding-Mode Control for Boost DC–DC Converters simulation simulation fails;''Derivative of state '1' in block 'power_BoostConverter_Adaptive_SMC_math/TSMC Controller/Integrator' at time 0.0 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances) ''
How to fix this error?
6 Comments
Ambe Harrison
on 23 Aug 2022
Hello,ahmet akgün. I am presently working on a Back steeping controller. Face thesame problem with the integrator. Please have you solved it.
If possible we may exchange more via email, ambeharrison2000@gmail.com
Zakarya Motea
on 10 Dec 2023
If your system has multiple chanels Try to tune them one by one. When tuning one chanel let the input for other chanels as zero.
Pavke
on 7 Mar 2023
Hello guys
I am doing a project in simulink and I have a problem. It is about braking an asynchronous motor with direct current, which I made (it works correctly), and it is necessary to connect that system to the distribution network (I use IEEE Bus 13). I connected the braking system of the asynchronous motor to the distribution network, and the system starts to work, it goes down from 1800 reversions and comes to 1480, and by the end of the simulation it stands at 1480, the engine will not brake and the simulation does not finish to the end and the following error occurs :
An error occurred while running the simulation and the simulation was terminated Caused by: Derivative of state '1' in block 'distributivnamrezamodel/Transfer Fcn' at time 0.991475799999991 is not finite. The simulation will be stopped. There may be a singularity in the solution. If not, try reducing the step size (either by reducing the fixed step size or by tightening the error tolerances).
How to fix this problems?
Thank you
3 Comments
Daniel Joseph
on 28 Mar 2023
Try to figure out why is your signal really large/infinite. Is divide by zero correct in this case? maybe you can substitute a very small value like 1e-6 instead of zero, using the switch example shown above by @Abhiram V. P. Premakumar, such that the solver does not get bogged down at very small /large values.
Anton
on 23 Apr 2023
Edited: Walter Roberson
on 22 May 2023
Hello, I have the same error. Please help me figure out what's wrong.
K1 = 2000;
K2 = 1;
Kk1 = 0.0012;
T1 = 0.2;
T2 = 0.005;
Tk1 = 0.0001;
T3 = 0.1;
Kt = 0.5;
tp = 0.280;
4 Comments
Sam Chak
on 23 Apr 2023
Edited: Sam Chak
on 23 Apr 2023
Hi @Saleh Altbawi, it is definitely not the solver. When a system is unstable, it doesn't matter what solver is chose. Here is a simple example of an unstable transfer function, with a positive pole.
Saleh Altbawi
on 24 Apr 2023
Hi. The system is not stable at specific time does not mean division on zero. If that true it should not work from the beginning. That mean solver at specific time could not convergence the transfer function. So try to use different kinds of solver. If does not work then try to update your system's parameters.
Yingxin Zhang
on 22 May 2023
hey i have the same problem, can you help me?
1 Comment
OLUWASEUN ADEKOYA
on 30 Jun 2023
Any luck on this yet?
I'm currently experiencing some similar issues with this as well. Thanks.
Hugo
on 2 Oct 2024
When I get this error, I can fix this by using the folling method :
- run your model using the step forward function (run step by step)
- Starting from the integrator block that makes the model stop, clik on signals to display values
- Track the signal until you find where the value diverges
- make the necessary corrections.
It works for me. I hope it will help you.
0 Comments
See Also
Categories
Find more on Configure Simulation Conditions in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!