sample error in simulink if else statement
19 views (last 30 days)
Show older comments
When i am using if loop in matlab simulink it shows the error Sample time 1 of 'bdc_2_CL/Subsystem/If Action Subsystem/PID Controller/u' does not match the sample time [0, 0] of the If block 'bdc_2_CL/Subsystem/If' controlling its execution. this error is coming only when i am trying to connect closed loop simulation. In open loop it is perfectly working.In closed loop i have just added one adder and discrete PID controller
1 Comment
ashwani gupta
on 9 Aug 2021
i will suggest a very crude way to tackle this problem. Just add one rate transition block before all the input signals of if block and it will resolve your problems.
Answers (2)
Sebastian Castro
on 25 Feb 2016
Conditionally executed subsystems like your "If" block are not guaranteed to execute at every time step.
According to your error message, the PID Controller block inside this subsystem is set to Discrete mode with at sample time of 1. However, the PID Controller block inside cannot take a deterministic rate because it's inside the "If" block.
Go to the PID Controller block and change its sample time to -1, for "Inherit". Does that work?
- Sebastian
0 Comments
kpb
on 26 Feb 2016
1 Comment
Sebastian Castro
on 26 Feb 2016
Looking at your error again, there seems to be some block "u" in that subsystem set to a sample time of 1. Maybe an Inport/Outport block?
See Also
Categories
Find more on Event Functions in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!