Connecting Electrical Nodes on Simulink?
22 views (last 30 days)
Show older comments
I'm trying to connect two circuit components to the same node, but the lines show up as red circles. Both blocks on both ends of the red connection are from the Simscape library. I tried the P-S-Simulink Converter box to no avail, so I'm not sure of the problem.
I included a picture as reference.

0 Comments
Accepted Answer
Sebastian Castro
on 14 Jun 2016
The blocks on the left are from SimPowerSystems while the blocks on the right are from Simscape, so they don't connect directly.
You can do either of the following
If you take approach #2, note that the SimElectronics semiconductor blocks are generally more detailed MOSFET models while the SimPowerSystems (the ones you have in your diagram) are piecewise linear and therefore simplified.
Up to you based on available toolboxes and the level of detail you want/need.
- Sebastian