Clear Filters
Clear Filters

Simulink variables initializtion problem

2 views (last 30 days)
https://www.mathworks.com/examples/simpower/mw/sps_product-power_PVarray_250kW-250-kw-grid-connected-pv-array
According to this example, all initial variables are defines in power_PVarray_250kW_param.m. It seems that this m files is called at starting simulation. But when I make new simulink file, and even copyed all contents in power_PVarray_250kW.slx, but it doesn't worked.
There are error messages, "Error evaluating parameter 'NominalPower' in 'aaa/120 kV // 25 kV 47 MVA'"
My question is
1. How can I define initial values in simulink using m file 2. Is any options or method to eliminate error messages?
Thanks.

Accepted Answer

Hyunsoo Park
Hyunsoo Park on 6 Feb 2017
I found answer;
Menu File -> Model Properties -> Callbacks. In the "PreLoadFcn", you can use a load command. Variables are still stored in MATLAB workspace.

More Answers (1)

Ben Rancici
Ben Rancici on 3 Feb 2017
Are you sure that 'NominalPower' is well defined in 'power_PVarray_250kW_param.m'? If so, have you launched this .m file before running the Simulink?
  1 Comment
Hyunsoo Park
Hyunsoo Park on 3 Feb 2017
Edited: Hyunsoo Park on 3 Feb 2017
In case of demonstration file, there is no need to launch m file. I want to automatically launch m file, when simulation starts

Sign in to comment.

Categories

Find more on Event Functions in Help Center and File Exchange

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!