Tuning transfer function to get only positive parameters using Simulink

10 views (last 30 days)
I have a transfer function with order three in both numerator and denominator. I am tuning the block using the control system tuner to find the best coefficients for the block for a desired function. My question is how to tell the tuner that the coefficients to be found must be positive values?
ex: tf=(a1*s+1)(a2*s+1)(a3*s+1)/((b1*s+1)(b2*s+1)(b3*s+1))
I want to find the values of the parameters all a & b to be positive values. Any idea? Thanks

Answers (1)

Sebastian Castro
Sebastian Castro on 17 Apr 2017
For all tuned blocks, you can expand the variable name and set their "Minimum" and "Maximum" values. If you set a minimum of 0, does it work?
Sebastian
  3 Comments
Ismaeel
Ismaeel on 18 Apr 2017
Edited: Ismaeel on 18 Apr 2017
Apparently, there is a technical issue to upload the picture. Anyway, this is what I got:
Numerator coefficients:
[-0.17873835660206 -0.241501688056885]
Denominator coefficients:
[1 0.372855801788186]
Ismaeel
Ismaeel on 18 Apr 2017
Edited: Ismaeel on 18 Apr 2017
I have soled my problem by changing the transfer function to multiple simple blocks (integral, gain, and sum) using the rules from control theory. Thanks Castro.