How to reset a subsystem with trigger type "function call" in unit test?

Hello everyone,
just I need to do an unit test for a subsystem with stateflow-charts. I have generated a test harness (test sequence) and tried to add some test cases.
However, I found I could not reset the subsystem. After running some test cases, the subsystem could not go back to initialization.
The subsystem has a trigger with following setting:
Trigger type: function-call; States when enabling: held; Propagate sizes of variable-size signals: During execution; Sample time type: triggered
This subsystem comes from a customer. Therefore, I hope that I don't need to change any thing in this subsystem.
A function-call scheduler was generated with send(trigger) automatically.
My question is:
how to reset the subsystem for each test case? I would like to know solutions for "test sequence" and "signal builder".
Thanks for your attention!
Best regards, XiC

1 Comment

If the "function-call" subsystem is driven by the stateflow chart, have you tried wrapping it inside a resettable subsystem?

Sign in to comment.

Answers (0)

Categories

Asked:

XiC
on 27 Sep 2017

Commented:

on 2 Oct 2017

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!