Simulink Test Sequence - How to Access Logged Signal Data
10 views (last 30 days)
Show older comments
Richard Hopple
on 7 May 2018
Answered: Richard Hopple
on 10 May 2018
I am writing a test using the "Test Sequence" block inside a test harness. The model being tested has a decent amount of logic that generates one signal that is used internally in that model. Due to the nature of the model, it does not need to be an actual output. It has both the "Log Signal Data" and "Test Point" checked on it. I am unsure of how to access that signal inside the "Test Sequence" block.
2 Comments
Rong Mi
on 9 May 2018
Hi, are you asking to use Test Sequence block to access some internal signals, such as inside of a subsystem block or a model reference block?
Test Sequence block requires a line to get connect to the signal, which means you cannot access to the signal wireless directly. Or you can use DSMW to write the signal to a DSM block and use DSMR inside of Test Sequence block to read the signal value.
Accepted Answer
More Answers (0)
See Also
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!