How to apply Vdc and Vdc reference to PI controller?
Show older comments
In the model I have attached herewith of "Grid Converter Implementation in a wind turbine based on Doubly Fed Induction Generator" if I want to get output on correspondence with voltage across capacitance between two bridge rectifier which is Vdc, how can i implement these in the controller of grid side? I just tried myself as i marked in the controller(Right hand side of main diagram,Untitled1.jpg and grid side controller,Untitled2.jpg).I tried to work on the basis of following link
https://www.youtube.com/watch?v=0uLjcCORlzA&t=1669s
Answers (1)
Sabin
on 11 Feb 2023
0 votes
The measured DC-link voltage, Vdc, is connected to both Vdc and Vdc_reference. This is not correct. Ther reference is the setpoint you want to track while Vdc is the measured value. The controller is then trying to follow the reference.
Categories
Find more on Simscape Electrical in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!