How to simplify the name of component's ports when importing an ARXML file in SIMULINK?

4 views (last 30 days)
When importing a composition or a component from an ARXML file, Simulink uses the following format for port naming: <name_of_port>_<name_of_variable>_<read|write>.
I want to systematically simplify this naming by displaying only <name_of_variable>
How can I configure simulink for this?

Accepted Answer

TAB
TAB on 5 Jun 2018
As far as I know, port naming is build-in into AUTOSAR toolbox and can not be configured or changed.
This is more or less becuase of naming convention of AUTOSAR architecture. If you generate a C- template file for your SWC from authoring tool, then generated port APIs are similar name_of_port_<name_of_variable>_<read|write>.
But good thing is, the exact names are required at root level only. We can change the port names at lower hierarchy (for example inside runnable).
In my case, I use scripts to import the arxml. And after the model is created script modifies the port names in lower hierarchy (not at root level) to short names like "name_of_variable". Thses ports with short names are used further for logic implementation.

More Answers (0)

Products


Release

R2018a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!