same input output signal name in simulink
10 views (last 30 days)
Show older comments
I want to make code below by model (or stateflow) using Code Generation
if( var > 10){
var = 10;
}
In this case, upper 'var' is input of chart(or subsystem) and lower 'var' is output of chart.
So, it occurs signal complication if I use same variables name or I can't make same name of chart's input and output.
I can make this if sentance by using two variables, but I hope to make this by using one.
Thanks for your help.
Sincerely,
TaeHee Kwun.
0 Comments
Accepted Answer
Phani Teja
on 16 Jul 2019
Edited: Phani Teja
on 16 Jul 2019
Yeh It can be possible with Data store memory block.
Make a Variable 'Var' in stateflow and change its scope to Data store memory .
You can also control the variable storage class by resolving data store memory with simulink signal.
The generated code looks like:
/* Real-time model */
RT_MODEL_Chart_T Chart_M_;
RT_MODEL_Chart_T *const Chart_M = &Chart_M_;
/* Model step function */
void Chart_step(void)
{
/* Chart: '<Root>/Chart' */
/* Re-use inputs */
if (Var > 10) {
/* NEW_PATTERN */
Var = 10;
}
/* End of Chart: '<Root>/Chart' */
}
2 Comments
More Answers (0)
See Also
Categories
Find more on Simulink Coder in Help Center and File Exchange
Products
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!