Hello,
I have measurement data and I'm fitting it against a differential equation system. In addition, I would like to calculate the two curves that include the measurements within the confidence interval.
In order to do this I have tried the following approach:
[Opts,resnorm,resid,exitflag,output,lambda,J] = lsqcurvefit(@main_fun,Starts,x,y,l_lim,u_lim);
Ci = nlparci(Opts,resid,'jacobian',J);
'Opts' contain two parameters that are to be fitted. In 'Ci' I also get as expected an upper and a lower limit for these values.
The limits are clearly too close to the values only for my sensation.
I have attached a figure of my results and a figure of my expectations.
I actually thought I was on the right track. Did I make a logical mistake?
Thank you and kind regards
Torsten
  5 Comments
Torsten Klement
Torsten Klement on 22 Oct 2019
Hi Adam Danz,
thank you very much for your work on this topic.
But shouldn't 95% of the generated data points be within the limits of the interval?
kind regards
Torsten

Sign in to comment.

Accepted Answer

Adam Danz
Adam Danz on 22 Oct 2019
Edited: Adam Danz on 22 Oct 2019
@Torsten Klement, (continuing from comments under the question)
There are 2 types of prediction intervals.
Confidence interval of the function value at x
In your current prediction interval calculation, you are computing the confidence interval for the estimated curve (function value) at each observation (x). To demonstrate, the 95% confidence interval of your paramter estimate (using nlparci) is CI = [0.035 0.052] which means the k_opt parameter may vary between [0.035 0.052] within the interval. The plot below shows a range of possible curves when the k_opt parameter is varied between those bounds. Then I add the 95% confidence interval for the estimated curve using your line of code (nlpredci). As you can see, it's roughly the bounds of the varied curve. See this example in the documentation which produces a similar result.
% The confidence interval on your parameter estimate is
CI = nlparci(k_opt,resid,'jacobian',J);
% CI = [0.035 0.052]
% which means the k_opt parameter may vary between [0.035 0.052] within the 95% CI
% Let's plot the function with k_opt parameter varying between those bounds
figure();
plot(t_data,Y_data(:,1),'xk') ;
hold on
param = linspace(CI(1),CI(2),20);
arrayfun(@(x)plot(t_data,mainFunc(x, t_data),'-'),param)
% Show the best-fit line
plot(t_data, mainFunc(k_opt, t_data), 'k--','linewidth',3)
% Now let's overlay the CI of the function
[ypred,delta] = nlpredci(@mainFunc,t_data,x,residual,'Jacobian',jacobian)
lower = ypred-delta;
upper = ypred+delta;
plot(t_data,[lower,upper],'b--', 'linewidth',2)
Prediction for new observations at x
To compute the prediction interval of new observations (that should always be larger than the confidence interval of the data), you need to use the PredOpt-observeration flag.
[ypred,delta] = nlpredci(@mainFunc,t_data,x,residual,'Jacobian',jacobian,'PredOpt','observation')
lower = ypred-delta;
upper = ypred+delta;
plot(t_data,[lower,upper],'r:', 'linewidth',2)
  3 Comments
Adam Danz
Adam Danz on 22 Oct 2019
Edited: Adam Danz on 23 Oct 2019
I wish we had some kind of indicator that an answer or comment is being written. Glad you caught it before investing time!

Sign in to comment.

More Answers (1)

Torsten Klement
Torsten Klement on 24 Oct 2019
Actually, this question is answered. As a bonus it would be great if someone could explain how to calculate the delta values from the Jacobi Matrix and the residuals. Unfortunately I can't find a mathematical description for it.
thanks again everybody.
Regards,
Torsten