XPC target with CAN-AC2-104(SOFTING)
3 views (last 30 days)
Show older comments
Hi everyone,
I am working with a CAN card (CAN-AC-PC104 by Softing) plugged to an Advantech PC104, more precisely the PCM-3343F-256A1E. I want to use the XPC environment(standalone Mode), but when trying to download the Simulink model to the PC104 I get the following error:
------------------------------------------------------------------------------- downloading CAN-AC2-104 firmware on board 1, -->Error in CANPC_reset_board_mb1:Error code=-1; Error Text: can’t open IniFile --------------------------------------------------------------------------------
Could someone help with this issue?
More info:
PC104 => Model: Advantech PCM-4153FZ-L0A2E CAN Card => Model: Softing CAN-AC2-PC104 Matlab => R2009b Compiler => Visual Studio 6.0
Thanks in advance!
1 Comment
Philip Lemmmink
on 1 Nov 2017
Hello y,
currently i facing the same Problem as you mentioned above. I try to run a simulink-real-time model (R2016b) on a old fashion target Hardware.
Could you find a solution to the Problem?
Best Regards
Answers (1)
Lucas Lebert
on 13 Nov 2017
This issue could occur if the "Memory base address" or the "I/O base address" in the "Setup" block being inaccessible by the target BIOS. Please ensure that the BIOS settings are as mentioned in the attached screenshots.
If the BIOS settings are not the issue, then take out the I/O card and then re-plug it back in. This should resolve the issue.
0 Comments
See Also
Categories
Find more on Target Computer Setup in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!