Hello,
i am autogenerating a PID code from simulink, but in the generated code i get some variable name which correponds to its root level block name.
How can i replace these root level block names by some meaning full names in generated code. For example ,
rtb_DeadZone_0 = rtb_Sum * rtb_Saturation + rtb_DeadZone * rtb_PID_Y_Out_Ratelimited;
OR
if (Select_OL) {
rtb_Sum = (real32_T)OL_X_Command;
rtb_DeadZone = (real32_T)OL_Y_Command;
}
i get above lines of code when i autogenerate it and bit hard to read and understand. How can i replace those autogenerated name like rtb_DeadZone_0 , rtb_Sum etc.
Thank you.
0 Comments
Accepted Answer
Fangjun Jiang
on 27 Jun 2020
If you want a particular variable name for a signal line in the model, double click the signal line, give it a name "MySignal", right click, select properties, chck "signal name must resolve to Simulink object". In base workspace, create a Simulink.Signal object, MySignal=Simulink.Signal. Then, set properties.
open MySignal
2 Comments
Fangjun Jiang
on 28 Jun 2020
The place to change is Ctrl+E, Code Generation, Identifiers. Change Local block output variables from rtb_$N$M to something else. But you don't have specifiic control, just one type of auto naming to another. Right click, select "what's this?" to see the meaning of those $ symbols.
There should be no problem if you break the link of the PID controller and label the signals inside, especially if you want to control the generated signal names.