'Decimation' Error in Simulink
14 views (last 30 days)
Show older comments
Hi all,
I hope you are well. When I run my Simulink model, I met the issue 'The 'Decimation' option must be a positive integer'. Does anyone know why it occurs?
Thank you for your help.
Di
2 Comments
Mathieu NOE
on 12 Oct 2020
well, you can resample with non integer values in matlab, but that is not doable in causal systems.
In simulink, decimation must always be performed with an integer decimation factor
look at the help
Accepted Answer
Fangjun Jiang
on 12 Oct 2020
Follow the link of the error message to find the involved block. You must have provied an incorrect number for the "Decimation" parameter, which is a factor, n, which writes data at every nth time that the block executes. It's value must be a positive integer.
3 Comments
Fangjun Jiang
on 15 Oct 2020
Edited: Fangjun Jiang
on 15 Oct 2020
It is weird it didn't tell the violating block.
Best way is to attach the model. If not, run the following code. 'f14' is a built-in example model. Observe the value and hopefully find the problematic block.
%%
f14;
blocks=find_system('f14','FollowLinks','On','LookUnderMasks','All','RegExp','On','Decimation','\w')
decimation=get_param(blocks,'Decimation')
More Answers (0)
See Also
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!