- Change the sample time of the Simulink signal where io(1) is located to a continuous sample time
- Use frest.createFixedTsSinestream to create a sinestream signal that has a single sample rate
when i run frestimate(mdl,io,in) , it comes out following warnings, what can i do~
17 views (last 30 days)
Show older comments
??? Error using ==> frestimate>LocalCheckDataTypeAndSampleTime at 532
In "frestimate(modelname,op,io,in)", the input signal "in" is a
frest.Sinestream signal which has parameter values for "Frequency" and
"SamplesPerPeriod" such that it inherently has multiple sample times.
Using such an input signal requires that samples rates belonging to the
Simulink signals where your linearization input and output points are
located are either continuous or fixed in minor time step and the
linearization I/O io(1) does not satisfy this requirement. Consider either
changing the sample time of Simulink signal where io(1) is located to
continuous sample time or using frest.createFixedTsSinestream utility to
create a sinestream signal that has a single sample rate.
Error in ==> frestimate>LocalSetupForSimulation at 379
isVarTs = LocalCheckDataTypeAndSampleTime(table,in,ModelParameterMgr);
Error in ==> frestimate at 94
[parammgr,SimulationPackage] =
LocalSetupForSimulation(model,io,op,in,numout,opts);
0 Comments
Answers (2)
Arnaud Miege
on 26 Apr 2011
The error message suggests two things, have you tried them?
Without seeing the model and the code, it's difficult to be more specific.
HTH,
Arnaud
5 Comments
Arnaud Miege
on 28 Apr 2011
Can you explain about the I/O points? Do you mean the inputs and outputs of the PID controller? Why openloop? What are you trying to get the frequency response of? Shouldn't the I/O points be at the top-level of the model, e.g. w* and w? Also, are you aware that you are using a discrete sample time of 1s for your PID controller, whereas your electrical model has been discretized with a sample time of 1e-5s? Is that really what you intend to do?
SimTec
on 26 Feb 2018
Dear Miege, How can we Change the sample time of the Simulink signal where io(1) is located to a continuous sample time, I right-click on the io and I could not see any parameter related to sample time best regards
2 Comments
Abdullah Al Masud
on 17 Jun 2019
Hello Zhao,
I am also having the same problem. Have you found any solution yet?
MULTAN007
on 7 May 2020
Hi,
James Zhao, TarikTech and Abdullah Al Masud, did you get the solution for this issue? I'm having same sitation. Thanks in advance for your response and time.