Simscape and Simulink connections
5 views (last 30 days)
Show older comments
I'm using Matlab R2019B and trying to combined some simulink blocks with simscape. I'm having a problem connecting the simscape models to each other and in some cases even with the PS-Simulink/Simulink-PS blocks. In particular I can't connect the outputs of a Three-Phase Rectifier with the inputs of a Three-Phase Inverter block. Can anyone tell me why this is happening and how to fix it?
0 Comments
Answers (1)
Raynier Suresh
on 16 Mar 2021
Hi, The PS-Simulink/Simulink-PS block is used to connect a physical signal to simulink ouput signal or vice versa, this cannot be used to connect two different simscape components. Try using the Average-Value Rectifier (Three-Phase) and Average-Value Inverter (Three-Phase) for your work you can connect these two directly. Refer the below links to know more about these blocks