simulink code inspector compatibility with parallel states in states
Show older comments
I have some state charts code that uses parallel states. I have been told that simulink code inspector is not compatible with parallel states. Is it still the case with SLCI in the newer versions? Is there a way to use SLCI with state chart parallel states? In my case there are about 20 parallel states each with execution order priority. I really don't want to re-code the architecture. Any ideas!
Many thanks :)
1 Comment
Sarthak
on 11 Nov 2026 at 14:27
Yes. In current releases, Simulink Code Inspector supports Stateflow states, including states using parallel decomposition. You should not need to restructure your parallel-state architecture solely to use SLCI. However, the chart must satisfy the Stateflow constraints documented for Simulink Code Inspector. You can run the SLCI compatibility checker to identify any other unsupported constructs in the model.
Answers (1)
Pat Canny
on 10 Nov 2026 at 0:08
0 votes
Categories
Find more on Environment and Clutter in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!