Three-phase permanent magnet synchronous machine - direct and quadrature currents and voltages
4 views (last 30 days)
Show older comments
Hi everybody,
I am simulating a PMSM motor by using this Simscape model . This model gives a measurement output that include quadrature and direct stator current.
I would like to know how the Clarke Park transform are implemented by this model, because those outputs (quadrature and direct currents) does not match the one I expect. In particular, what I expect is this:
and I evaluated the dq quantities starting from the phase quantities that the model gives as output. But the computed dq quantities does not match the one that the model gives as output.
0 Comments
Answers (1)
Dakai Hu
on 22 Apr 2021
Hello Giovanni,
The Clark and Park transformation implemented in our Simscape blocks are based on "magnitude invariant" convention. It uses exactly the same eqations you've written down. When you pointed out that the "computed dq quantities does not match the one that the model gives as output", would you be able to provide a comparison model that we can use to verify ?
0 Comments
See Also
Categories
Find more on Specialized Power Systems in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!