Bypassing the internal (Linear) observer in MPC toolbox 3
Show older comments
I wish to use my designed non-linear Observer with the MPC block (MPC toolbox v3.1)for the real-time control of a system. However, the MPC block contains its own linear observer for state estimation.
How can I bypass (disable) the internal linear observer of the MPC block in Simulink for real-time implementation.
Answers (1)
Bill Tubbs
on 24 May 2021
Edited: Bill Tubbs
on 24 May 2021
0 votes
Might be 10 years too late but I had this question and it looks like you can set the following check box below in the Simulink MPC block parameters:

When I did this, the usual 'measured output' inport is replaced with an inport labelled `x[k|k]` for the state estimates from some other observer.
[I'm using MATLAB 2019b.]
Categories
Find more on Controller Creation in Help Center and File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!