Stop Simulink simulation base don a variable value
22 views (last 30 days)
Show older comments
Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance
0 Comments
Accepted Answer
Arnaud Miege
on 20 Jun 2011
Or use a Stop Simulation block. You will also need to construct the logic to create a boolean input signal to the block.
HTH,
Arnaud
0 Comments
More Answers (2)
Fangjun Jiang
on 20 Jun 2011
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.