Stop Simulink simulation base don a variable value

22 views (last 30 days)
Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance

Accepted Answer

Arnaud Miege
Arnaud Miege on 20 Jun 2011
Or use a Stop Simulation block. You will also need to construct the logic to create a boolean input signal to the block.
HTH,
Arnaud

More Answers (2)

Fangjun Jiang
Fangjun Jiang on 20 Jun 2011
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.

Javier Guiterrez
Javier Guiterrez on 20 Jun 2011
Thank you for all the answers. the stop block is enough for my case. Thanks