如何设置可以让storage class 为 internalCalPrm的标定参数在代码生成的时候保持为参数而不是rte函数
hi Rte_CData_xxx 这个是标准的autosar接口,把storage class改了不使用 internalCalPrm,改成auto就可以了吧
2 years ago | 0
Autosar client service function calls not simulate in Simulink model
hi this function "CAN1_RequestComMode" seems not be defined properly, you can create a stub function and define it in XXX.c...
2 years ago | 0
Question
How to open the Generate Calibration Files tool to generate ASAP2 files in 2021a
hi it is mentioned in 2021a release note that "ASAP2 system target file being removed, use the Generate Calibration Files t...
2 years ago | 1 answer | 0
1
answerSimulink Modell terminates with " Reference to non-existent field 'accessInfoMap' ", when a MATLAB Function block is involved
also having similar issue: "Reference to non-existent field 'AUTOSAR4' " By deleting slprj folder fixed this issue.
5 years ago | 0
How to generate 'Rte_Pim_xxxxx' API with Embedded Coder (autosar.tlc)
i have find the answers: define Abcdef as Autosar.signal then chose per instance memory in the storage class item.
6 years ago | 0
Question
How to generate 'Rte_Pim_xxxxx' API with Embedded Coder (autosar.tlc)
Hello, does anyone have a guide about how to configure a signal as Rte_Pim API, we already defined a struct(pim) in our Rte_Typ...
6 years ago | 1 answer | 0