I am a Mechanical Engineer I working at Raytheon. I'm currently focused on modeling a liquid cooling system.

Statistics

  • Thankful Level 2
  • Thankful Level 1

View badges

Feeds

View by

Question


I'm not getting an expected temperature/pressure output from cooling a 600 [F] copper object [FEEDBACK REQUEST]
Context: A hot metal object has a hose coiled around it so that refrigerant passing through can carry the heat away. I have the ...

2 years ago | 1 answer | 0

1

answer

Question


Is this an appropriate way to model the pressure/temperature drop across an elbow joint? Critiques requested
I'm working on modeling pressure changes across elbow joints, and I feel like there might be a better way to accomplish this tha...

2 years ago | 1 answer | 0

1

answer

Question


How can I consider the changing temperature of a copper object that is being cooled by coiling a pipe around the outside surface?
Hi, It looks like many of the heat exchangers offered in simscape require another fluid or gas. So that doesnt quite get the jo...

3 years ago | 1 answer | 0

1

answer