photo

Guilherme Costa Nascimento

MathWorks

Last seen: Today Active since 2023

Followers: 0   Following: 0

Statistics

All
  • Knowledgeable Level 2
  • 3 Month Streak
  • First Answer
  • Solver

View badges

Feeds

View by

Answered
Is there any autosave option for tests results in test manager?
Assuming you are using Simulink Test: If you need to save the results themselves rather than a report, use sltest.testmanager.e...

20 days ago | 0

Answered
I am trying to write a script to convert a test case from baseline to Real- Time using test manager. However I am unable to do it programmatically. Is there any way to do it ?
There's no way to programmatically convert an existing test case into a Real-Time test case, but when first creating a test prog...

2 months ago | 0

| accepted

Answered
Link req to verify statement in a test sequence
Hi Diana, There's no way to link a requirement to individual verify statements in the Test Sequence block. Requirements can onl...

4 months ago | 0

Answered
Test coverage report shows same condition with 2 different sets of coverage stats
Hi Cody, Thanks for sending the model. In Stateflow, if you do not specify the type of action for your code, it will be execute...

5 months ago | 0

| accepted

Answered
Issue with Configuring Plant Model from ECU TEST tool
Hi Dhivya, This could be happening because the Simulink Test Support Package for ASAM XIL is picking up the wrong version of MA...

7 months ago | 1

Answered
R2020b : coverage explorer cumulative data
Hi Nicolas, You can aggregate coverage results programmatically using the + operator. You can find more details in this example...

7 months ago | 0

Answered
How to determine the subset of a test suite which needs to be rerun due to changes to a project's codebase?
I recommend you take a look at the CI/CD Automation support package: https://www.mathworks.com/products/ci-cd-automation.html O...

10 months ago | 0

Answered
How Generate Code Coverage Report in Cobertura XML Format for a .slx file
Hi Diana, For Simulink models you can use the sltest.plugins.ModelCoveragePlugin. This documentation page has an example of how...

11 months ago | 0

| accepted

Answered
test harness input for "read from file"
Hi Bertug, As you are using image files, you need to use the "Parameter Overrides" section to change the name of the image you ...

12 months ago | 0

Answered
Load nonfinite (Inf or NaN) data into simulink simulation
The only way that I know of to bring in NaN and Inf data into Simulink is with the Playback block, available starting in R2022b:...

1 year ago | 0

Answered
Multi-Dimension Matrix input for Simulink Test R2022a
Yes, you can create multidimensional signals in the Signal Editor. In your data, every column is treated as a separate "sub"-sig...

1 year ago | 0

Solved


Determine whether a vector is monotonically increasing
Return true if the elements of the input vector increase monotonically (i.e. each element is larger than the previous). Return f...

1 year ago

Answered
How can I measure Equivalence Class Coverage for a Simulink model?
Measuring Equivalence Class Coverage is not natively supported in Simulink Coverage, but we have developed an intial solution fo...

1 year ago | 0

| accepted

Question


How can I measure Equivalence Class Coverage for a Simulink model?
Some signals in my model are partitioned into different equivalence classes. When testing the model, each of my test cases targe...

1 year ago | 1 answer | 0

1

answer